PNEUTRONICS BOARD UPGRADE

ADVANTAGES
  • Allows 1 volt command VDC increment adjustments from 0-15 psi
  • The 0-15psi pressure comes out of the front of the board to eliminate leaks at the o-rings which affects pad conditioner downforce.
  • The unit can be returned for calibration re-certification.
 
BALANCEWORX UPGRADE           OEM BOARD--OBSOLETE!
 

LOOK UP TABLES

AO Set Voltage
AO Set Voltage
AI Feedback Voltage
 
AO Set Voltage
AO Set Voltage
AI Feedback Voltage
 
(Volts)
(PSI)
(Volts)
(Volts)
(PSI)
(Volts)
0.0
0
0
0.0
variable
variable
1.0
0
1
0.2
variable
variable
2.0
1.666
2
0.4
variable
variable
3.0
3.333
3
.06
variable
variable
4.0
5
4
1.0
variable
variable
5.0
6.666
5
1.2
variable
variable
6.0
8.333
6
1.4
variable
variable
7.0
0
7
1.8
variable
variable
8.0
11.66
8
2.0
variable
variable
9.0
13.333
9
2.2
variable
variable
10.0
15
10
to 10 vdc
variable
variable
Example-of the Balanceworx upgrade where you can use a standard look-up table that can be entered by hand exactly as you see above using the ideal parameters for the look-up table.   Example of the calibration of a Pneutronics card using the RPM3 calibration box through the serial interface on the CMP tool. The RPM3 box will calibrate out non-linear devices but will also mask leaks in the system. The average time to calibrate one channel is 20 minutes using this method on two channels. This can mean an additional 40 minutes of calibration time.
 

IDEAL PRESSURE CONTROLL

Example of the calibration data from the factory from a unit in production. You can see that all actual pressure are within .03 psi of ideal pressure.

Command VDC
Ideal Pressure
Actual Pressure
Command VDC
Ideal Pressure
Actual Pressure
0.0
0
0.000
0
0
0.000
1.0
0
0.000
1
0
0.000
2.0
1.666
1.660
2
1.666
1.661
3.0
3.333
3.317
3
3.333
3.318
4.0
5
4.977
4
5
4.978
5.0
6.666
6.640
5
6.666
6.640
6.0
8.333
8.305
6
8.333
8.304
7.0
10
9.974
7
10
9.973
8.0
11.666
11.645
8
11.666
11.646
9.0
13.333
13.320
9
13.333
13.320
10
15
15.000
10
15
15.00

 

 

 

           OEM BOARD                              BALANCEWORX

UPGRADE INCLUDES


  

 
 

©2007 BALANCEWORX INC.